Technology > MEAP > Login to SMS > Login by Password Authentication
Technology > MEAP > Login to SMS > Login by Password Authentication
Login to SMS
SMS login may be done by entering a password for authentication, or by authentication via
the Remote Login Service (RLS) login window (RLS authentication). Settings can be changed
to allow either only one of these methods or both of them.
SMS login window (password authentication)
RLS login window
(user name/ password authentication)
Login method Authentication method Authentication service name Users who may log in
Password
authentication
Password authentication SMS Installer Service
(Password Authentication)
Users who know the
SMS login password
RLS login
SSO-H/SSO(SDL also
possible)
SMS Installer Service(Remote
Login Service Authentication)
Users registered as
administrators with
SSO-H/ SSO
NOTE:
If Default Authentication is selected as the device authentication method, 'RLS
Authentication' is not selectable as SMS Login method. Also, if 'RLS Authentication' is
selected, the device authentication method (Default Authentication, SDL, SSO) cannot
be changed.
F-2-203
T-2-98
■
Login by Password Authentication
In the SMS login window, enter the password for authentication. Only one password can be
registered with SMS. The login procedures are as follows.
1) Access SMS from the browser of a PC on the same network as the MEAP device. The URL
is as follows.
URL: http://<MEAP Device IP address>:8000/sms/
Ex.) http://172.16.188.240:8000/sms/
NOTE:
• The default password is "MeapSmsLogin." (The password is case-sensitive.)
• When you want to change the display original language, change in the box in the right of
the screen. This setting is not affect by the setting of the language of the device.
F-2-204
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...