4
4
4-76
4-76
Parts Replacement and Cleaning > Main Unit > Pulling Out Process Unit
Parts Replacement and Cleaning > Main Unit > Pulling Out Process Unit
Caution :
When the drum home
position flag is set
downward and installed,
be sure that the flag part
is inserted to the [A] part
of the drum home position
sensor.
F-4-87
8) Fit the protrusion of the drum home position detection flag into the groove of the drum shaft.
• 1 spring.
• 1 stepped screw.
Caution :
When tightening the screw, be sure to tighten it while
holding the drum home position detection flag. (If the
drum is rotated clockwise, the drum surface might
scratch).
F-4-88