7
7
7-8
7-8
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E003 0006 05
Title
Error in low temperature detection
Description
of detection
Error in low temperature detection of external heat upper
roller. (Detected temperature of sub thermistor on the external
heat upper roller is 60 deg C or lower against the target for 1
sec.)
Measures 1. Clean the external heat upper roller sub thermistor.*
2. Replace the external heat roller thermistor.*
3. Replace the external heat heater 1.*
4. Replace the fixing heater control PCB.
*: When the counter value of the external heat upper roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E003 0007 05
Title
Error in low temperature detection
Description
of detection
Error in low temperature detection of external heat lower
roller. (Detected temperature of main thermistor on the
external heat lower roller is 60 deg C or lower against the
target for 1 sec.)
Measures 1. Clean the external heat lower roller main thermistor.*
2. Replace the external heat roller thermistor.*
3. Replace the external heat heater 2.*
4. Replace the fixing heater control PCB.
*: When the counter value of the external heat lower roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E003 0008 05
Title
Error in low temperature detection
Description
of detection
Error in low temperature detection of external heat lower
roller. (Detected temperature of sub thermistor on the external
heat lower roller is 60 deg C or lower against the target for 1
sec.)
Measures 1. Clean the external heat lower roller sub thermistor.*
2. Replace the external heat roller thermistor.*
3. Replace the external heat heater 2.*
4. Replace the fixing heater control PCB.
*: When the counter value of the external heat lower roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E003 9999 05
Title
Error in low temperature detection
Description
of detection
Before an error is detected by other low temperature
detection error, the relay was turned OFF by the hardware
detection.
Measures This error does not usually occur because software detection
is performed before hardware detection.
Code
Detail
Code
Location
Item
Description
E004 0011
05
Title
Heater ON/OFF detection circuit error
Description
of detection
ON/OFF detection circuit error of the fixing heater (main)
Measures 1. Check the fixing heater connector.
2. Replace the fixing heater.
3. Replace the fixing heater control PCB.
E004 0012 05
Title
Heater ON/OFF detection circuit error
Description
of detection
ON/OFF detection circuit error of the fixing heater (sub)
Measures 1. Check the fixing heater connector.
2. Replace the fixing heater.
3. Replace the fixing heater control PCB.
E004 0013 05
Title
Heater ON/OFF detection circuit error
Description
of detection
ON/OFF detection circuit error of the pressure roller heater
(main)
Measures 1. Check the pressure roller heater connector.
2. Replace the pressure roller heater.
3. Replace the fixing heater control PCB.
E004 0014 05
Title
Heater ON/OFF detection circuit error
Description
of detection
ON/OFF detection circuit error of the external heat heater 1
(main)
Measures 1. Check the external heat heater 1 connector.
2. Replace the external heat heater 1.*
3. Replace the fixing heater control PCB.
*: When the counter value of the external heat upper roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E004 0015 05
Title
Heater ON/OFF detection circuit error
Description
of detection
ON/OFF detection circuit error of the external heat heater 2
(main)
Measures 1. Check the external heat heater 2 connector.
2. Replace the external heat heater 2.*
3. Replace the fixing heater control PCB.
*: When the counter value of the external heat lower roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
E004 0016 05
Title
Heater ON/OFF detection circuit error
Description
of detection
ON/OFF detection circuit error of the external heat heater 1
(sub)
Measures 1. Check the external heat heater 1 connector.
2. Replace the external heat heater 1.*
3. Replace the fixing heater control PCB.
*: When the counter value of the external heat upper roller is
less than 1,000,000. Replace the external heat roller unit in
the case of 1,000,000 or more.
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...