Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E260 0112
05
Title
Fixing sub driver PCB 1 5V error (supported by DC Controller
Ver 49.04 or later)
Description
of detection
When checking the power supply detection port at intervals
of 100 msec at power-on, an error was detected 5 times in
a row (excluding the case where the Front Door is open/unit
has been removed).
When checking the power supply error detection port at
intervals of 100 msec at the time that an error was detected
in the Fan Motor, an error was detected more than 5 times
out of 10 (excluding the case where the Front Door is open/
unit has been removed).
Measures 1. Check the connector (J4350)/harnesses of the Fixing sub
driver PCB 1 (PCB9).
2. Check the connectors (J801, J800)/harnesses of the Fixing
main driver PCB (PCB8).
3. Check the connectors (J1102, J1120)/harnesses of the
Power relay PCB (PCB14).
E260 0200 05
Title
Pickup feed driver PCB 12V error (supported by DC
Controller Ver 49.04 or later)
Description
of detection
When checking the power supply detection port at intervals
of 100 msec at power-on, an error was detected 5 times in
a row (excluding the case where the Front Door is open/unit
has been removed).
When checking the power supply error detection port at
intervals of 100 msec at the time that an error was detected
in the Fan Motor, an error was detected more than 5 times
out of 10 (excluding the case where the Front Door is open/
unit has been removed).
Measures 1. Check the connector (J400)/harnesses of the Pickup feed
driver PCB (PCB3).
2. Check the connectors (J1103, J1120)/harnesses of the
Power relay PCB (PCB14).
3. Check the connectors (J1309, J1513)/harnesses of the
12V power PCB (PCB17).
Code
Detail
Code
Location
Item
Description
E260 0202 05
Title
Reverse delivery driver PCB 12V error (supported by DC
Controller Ver 49.04 or later)
Description
of detection
When checking the power supply detection port at intervals
of 100 msec at power-on, an error was detected 5 times in
a row (excluding the case where the Front Door is open/unit
has been removed).
When checking the power supply error detection port at
intervals of 100 msec at the time that an error was detected
in the Fan Motor, an error was detected more than 5 times
out of 10 (excluding the case where the Front Door is open/
unit has been removed).
Measures 1. Check the connector (J500)/harnesses of the Reverse
delivery driver PCB (PCB7).
2. Check the connectors (J1106, J1120)/harnesses of the
Power relay PCB (PCB14).
3. Check the connectors (J1309, J1513)/harnesses of the
12V power PCB (PCB17).
E260 0204 05
Title
Fixing main driver PCB 12V error (supported by DC Controller
Ver 49.04 or later)
Description
of detection
When checking the power supply detection port at intervals
of 100 msec at power-on, an error was detected 5 times in
a row (excluding the case where the Front Door is open/unit
has been removed).
When checking the power supply error detection port at
intervals of 100 msec at the time that an error was detected
in the Fan Motor, an error was detected more than 5 times
out of 10 (excluding the case where the Front Door is open/
unit has been removed).
Measures 1. Check the connector (J800)/harnesses of the Fixing main
driver PCB (PCB8).
2. Check the connectors (J1102, J1120)/harnesses of the
Power relay PCB (PCB14).
3. Check the connectors (J1309, J1513)/harnesses of the
12V power PCB (PCB17).
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...