7
7
7-159
7-159
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E867 0002 11
Title
Error in low temperature of upper deck floatation air heater
Description
of detection
Low temperature is detected on the upper deck floatation air
heater.
Measures 1. Replace the upper deck floatation air heater.
2. Replace the AC relay PCB.
E867 0002 12
Title
Error in low temperature of upper deck floatation air heater
Description
of detection
Low temperature is detected on the upper deck floatation air
heater.
Measures 1. Replace the upper deck floatation air heater.
2. Replace the AC relay PCB.
E867 0002 13
Title
Error in low temperature of upper deck floatation air heater
Description
of detection
Low temperature is detected on the upper deck floatation air
heater.
Measures 1. Replace the upper deck floatation air heater.
2. Replace the AC relay PCB.
E867 0002 21
Title
Error in low temperature of upper deck floatation air heater
Description
of detection
Low temperature is detected on the upper deck floatation air
heater.
Measures 1. Replace the upper deck floatation air heater.
2. Replace the AC relay PCB.
E867 0101 11
Title
Error in high temperature of middle deck floatation air heater
Description
of detection
High temperature is detected on the middle deck floatation air
heater.
Measures 1. Replace the middle deck floatation air heater.
2. Replace the AC relay PCB.
E867 0101 12
Title
Error in high temperature of middle deck floatation air heater
Description
of detection
High temperature is detected on the middle deck floatation air
heater.
Measures 1. Replace the middle deck floatation air heater.
2. Replace the AC relay PCB.
E867 0101 13
Title
Error in high temperature of middle deck floatation air heater
Description
of detection
High temperature is detected on the middle deck floatation air
heater.
Measures 1. Replace the middle deck floatation air heater.
2. Replace the AC relay PCB.
E867 0101 21
Title
Error in high temperature of middle deck floatation air heater
Description
of detection
High temperature is detected on the middle deck floatation air
heater.
Measures 1. Replace the middle deck floatation air heater.
2. Replace the AC relay PCB.
E867 0102 11
Title
Error in low temperature of middle deck floatation air heater
Description
of detection
Low temperature is detected on the middle deck floatation air
heater.
Measures 1. Replace the middle deck floatation air heater.
2. Replace the AC relay PCB.
Code
Detail
Code
Location
Item
Description
E867 0102 12
Title
Error in low temperature of middle deck floatation air heater
Description
of detection
Low temperature is detected on the middle deck floatation air
heater.
Measures 1. Replace the middle deck floatation air heater.
2. Replace the AC relay PCB.
E867 0102 13
Title
Error in low temperature of middle deck floatation air heater
Description
of detection
Low temperature is detected on the middle deck floatation air
heater.
Measures 1. Replace the middle deck floatation air heater.
2. Replace the AC relay PCB.
E867 0102 21
Title
Error in low temperature of middle deck floatation air heater
Description
of detection
Low temperature is detected on the middle deck floatation air
heater.
Measures 1. Replace the middle deck floatation air heater.
2. Replace the AC relay PCB.
E867 0201 11
Title
Error in high temperature of lower deck floatation air heater
Description
of detection
High temperature is detected on the lower deck floatation air
heater.
Measures 1. Replace the lower deck floatation air heater.
2. Replace the AC relay PCB.
E867 0201 12
Title
Error in high temperature of lower deck floatation air heater
Description
of detection
High temperature is detected on the lower deck floatation air
heater.
Measures 1. Replace the lower deck floatation air heater.
2. Replace the AC relay PCB.
E867 0201 13
Title
Error in high temperature of lower deck floatation air heater
Description
of detection
High temperature is detected on the lower deck floatation air
heater.
Measures 1. Replace the lower deck floatation air heater.
2. Replace the AC relay PCB.
E867 0201 21
Title
Error in high temperature of lower deck floatation air heater
Description
of detection
High temperature is detected on the lower deck floatation air
heater.
Measures 1. Replace the lower deck floatation air heater.
2. Replace the AC relay PCB.
E867 0202 11
Title
Error in low temperature of lower deck floatation air heater.
Description
of detection
Low temperature is detected on the lower deck floatation air
heater.
Measures 1. Replace the lower deck floatation air heater.
2. Replace the AC relay PCB.
E867 0202 12
Title
Error in low temperature of lower deck floatation air heater.
Description
of detection
Low temperature is detected on the lower deck floatation air
heater.
Measures 1. Replace the lower deck floatation air heater.
2. Replace the AC relay PCB.
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...