7
7
7-166
7-166
Error Code > Jam Code > imagePRESS 1135+/1125+/1110+
Error Code > Jam Code > imagePRESS 1135+/1125+/1110+
ACC ID Jam Code
Type
Sensor Name / Jam Type
Sensor ID
00
0A13
POWER ON Reverse sensor
PS64
00
0A14
POWER ON Delivery sensor 1
PS66
00
0A15
POWER ON Delivery sensor 2
PS67
00
0A16
POWER ON Delivery sensor 3
PS77
00
0A17
POWER ON POD deck path sensor
PS26
00
0A18
POWER ON Reverse vertical path sensor 1
PS79
00
0A19
POWER ON Reverse vertical path sensor 2
PS80
00
0A1A
POWER ON Reverse vertical path sensor 3
PS81
00
0A1B
POWER ON Reverse vertical path sensor 4
PS82
00
0A1C
POWER ON Reverse sensor 1
PS98
00
0A1D
POWER ON Reverse sensor 2
PS100
00
0A1E
POWER ON Delivery vertical path sensor 1
PS102
00
0A1F
POWER ON Delivery vertical path sensor 2
PS103
00
0A20
POWER ON Delivery vertical path sensor 3
PS104
00
0A21
POWER ON Delivery vertical path sensor 4
PS148
00
0A22
POWER ON Decurler outlet sensor
PS76
00
0A23
POWER ON Duplexing delivery sensor 2
PS85
00
0A24
POWER ON Duplexing delivery sensor 3
PS86
00
0A25
POWER ON Duplexing delivery sensor 4
PS87
00
0A26
POWER ON Duplexing delivery sensor 5
PS88
00
0A27
POWER ON Duplexing delivery sensor 6
PS89
00
0A28
POWER ON Duplexing delivery sensor 7
PS90
00
0A29
POWER ON Duplexing delivery sensor 8
PS901
00
0A2A
POWER ON Delivery inlet sensor
PS168
00
0A2B
POWER ON Escape path sensor
PS28
00
0A2D
POWER ON Escape path sensor 2
PS171
00
0B00
DOOR OP
Door open
DOOR OP
00
0C2D
SEQ NG
Stop due to jam accompanied with sequence
error
SEQ NG
00
0C90
SEQ NG
Stop due to jam accompanied with sequence
error
SEQ NG
00
0C91
SEQ NG
Stop due to jam accompanied with sequence
error
SEQ NG
00
0C92
SEQ NG
Stop due to jam accompanied with sequence
error
SEQ NG
00
0CA0
SEQ NG
Stop due to jam accompanied with sequence
error
SEQ NG
ACC ID Jam Code
Type
Sensor Name / Jam Type
Sensor ID
00
0CF1
RETRY ERR Stop due to jam when operation/control error
is detected (1st time)
RETRY ERR
00
0CF2
RETRY ERR Stop due to jam when operation/control error
is detected (1st time)
RETRY ERR
00
0CFE
RETRY ERR Stop due to jam when operation/control error
is detected (1st time)
RETRY ERR
00
0CFF
SEQ NG
Stop due to jam accompanied with sequence
error
SEQ NG
00
0D91
MEDIA NG
Image standard sensor for transparency,
Image standard sensor
PS41,42
00
0D92
OHP NG
Image standard sensor for transparency,
Image standard sensor
PS41,42
00
0D93
OHP NG
Image standard sensor for transparency,
Image standard sensor
PS41,42
00
2F00
OTHER
Jam due to options
OTHER
T-7-13
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...