8
8
8-28
8-28
Service Mode > COPIER > DISPLAY (Status Display Mode) > CCD
Service Mode > COPIER > DISPLAY (Status Display Mode) > CCD
■
CCD
COPIER> DISPLAY> CCD
TARGET-B
Shading target value (B)
Lv.2 Details
Displaying the shading target value in Blue.
Continuous display of 0 (minimum) or FFFF (maximum) can
determine failure of the reader controller PCB.
Use case
• When replacing the reader controller PCB
• When the scanned image is faulty
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to FFFF
Appropriate target value 512 to 2047
TARGET-G
Shading target value (G)
Lv.2 Details
Displaying the target value in Green.
Continuous display of 0 (minimum) or FFFF (maximum) can
determine failure of the reader controller PCB.
Use case
• When replacing the reader controller PCB
• When the scanned image is faulty
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to FFFF
Appropriate target value 512 to 2047
TARGET-R
Shading target value (R)
Lv.2 Details
Displaying the shading target value in Red.
Continuous display of 0 (minimum) or FFFF (maximum) can
determine failure of the reader controller PCB.
Use case
• When replacing the reader controller PCB
• When the scanned image is faulty
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to FFFF
Appropriate target value 512 to 2047
GAIN-OB
Gain level of img sensr odd bit(B): frnt
Lv.2 Details
Displaying the Blue gain level adjustment value in odd-numbered bit
on CMOS sensor of front side scanner unit.
Continuous display of upper limit can determine a failure of the
scanner unit/reader controller PCB.
Use case
• When replacing the reader controller PCB
• When the scanned image is faulty
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to FFFF
Appropriate target value 16 to 246
COPIER> DISPLAY> CCD
GAIN-OG
Gain level of img sensr odd bit(G): frnt
Lv.2 Details
Displaying the Green gain level adjustment value in odd-numbered
bit on CMOS sensor of front side scanner unit.
Continuous display of upper limit can determine a failure of the
scanner unit/reader controller PCB.
Use case
• When replacing the reader controller PCB
• When the scanned image is faulty
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to FFFF
Appropriate target value 16 to 246
GAIN-OR
Gain level of img sensr odd bit(R): frnt
Lv.2 Details
Displaying the Red gain level adjustment value in odd-numbered bit
on CMOS sensor of front side scanner unit.
Continuous display of upper limit can determine a failure of the
scanner unit/reader controller PCB.
Use case
• When replacing the reader controller PCB
• When the scanned image is faulty
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to FFFF
Appropriate target value 16 to 246
GAIN-EB
Gain level of img sensr even bit(B) frnt
Lv.2 Details
Displaying the Blue gain level adjustment value in even-numbered
bit on CMOS sensor of front side scanner unit.
Continuous display of upper limit can determine a failure of the
scanner unit/reader controller PCB.
Use case
• When replacing the reader controller PCB
• When the scanned image is faulty
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to FFFF
Appropriate target value 16 to 246
GAIN-EG
Gain level of img sensr even bit(G) frnt
Lv.2 Details
Displaying the Green gain level adjustment value in even-numbered
bit on CMOS sensor of front side scanner unit.
Continuous display of upper limit can determine a failure of the
scanner unit/reader controller PCB.
Use case
• When replacing the reader controller PCB
• When the scanned image is faulty
Adj/set/operate method N/A (display only)
Display/adjust/set range 0 to FFFF
Appropriate target value 16 to 246
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Page 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...