4
4
4-83
4-83
Parts Replacement and Cleaning > Main Unit > Pulling Out ITB Unit
Parts Replacement and Cleaning > Main Unit > Pulling Out ITB Unit
Pulling Out ITB Unit
<Preparation>
1) Open the Front Left Cover and the Front Right
Cover.
2) Remove Process Unit Cover.
1) Turn the ITB release lever in the direction of the arrow.
ITB release lever
F-4-109
Caution :
Be sure to return the
ITB release lever to
pressured condition after
the work done, otherwise
it might cause error in the
intermediate transfer belt
displacement control and
transfer failure.
ITB release lever
F-4-110