7
7
7-188
7-188
Error Code > Alarm Code > Alarm Code Details
Error Code > Alarm Code > Alarm Code Details
Alarm Code
Alarm Code Details
Location Code
Description
Detailed description
00
- 0246 Error code display (4-digit) Fails to write into software counter PCB.
00
- 0247 Error code display (4-digit) Fails to repair the data of software counter.
02
- 0020 Front side DADF dust
correction occurs
Set : If there is DADF dust correction in the front
side roller during DADF between sheet.
02
- 0021 Back side DADF dust
correction occurs
Set : If there is DADF dust correction in the back
side roller during DADF between sheet.
04
- 0001 At ACC connection, re-
pickup does not work
normally (full).
04
- 0002 At ACC connection, re-
pickup does not work
normally (no paper).
04
- 0037 POD: Upper deck lifter
motor does not descend.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0038 POD: Lifter lower limit
sensor of upper deck is
broken.
(Lifter does not descend.)
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0039 POD: Upper deck lifter
motor does not ascend.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0040 POD: Lifter lower limit
sensor of upper deck is
broken.
(Lifter does not ascend.)
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0041 POD: Paper surface sensor
of upper deck is broken.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0042 POD: Lifter upper limit
sensor of upper deck
exceeds the upper limit.
Operation: Alarm is displayed while normal
operation is kept.
How to release: Open/close the deck to release
04
- 0043 POD: Lifter lower limit
sensor of upper deck
exceeds the lower limit.
Operation: Upper deck is not used/lifter is lifted to
the lowest position.
How to release: Turn OFF/ON to release
04
- 0044 POD: Remain level count
of upper deck exceeds the
upper limit.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0045 POD: Remain level count
of upper deck exceeds the
lower limit.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
Location Code
Description
Detailed description
04
- 0046 POD: Supply position
sensor flag of upper deck is
broken.
Operation: Upper deck is not used/upper deck lifter
motor is stopped.
How to release: Turn OFF/ON to release
04
- 0047 POD: Connector of supply
position sensor on upper
deck is disconnected.
Operation: Alarm is displayed while normal
operation is kept.
How to release: Open/close the deck to release
04
- 0048 POD: Connector of right
separation fan on upper
deck is disconnected.
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0049 POD: Right separation fan
of upper deck: end of life/
breakage of fan
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0050 POD: Connector of left
separation fan on upper
deck is disconnected.
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0051 POD: Left separation fan
of upper deck: end of life/
breakage of fan
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0052 POD: Connector of right
floatation fan on upper deck
is disconnected.
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0053 POD: Right floatation fan
of upper deck: end of life/
breakage of fan
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0054 POD: Connector of middle
floatation fan on upper deck
is disconnected.
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0055 POD: Middle floatation fan
of upper deck: end of life/
breakage of fan
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0056 POD: Auto adjustment of
floatation fan is failed on
upper deck.
Operation: Alarm is displayed while normal
operation is kept.
How to release: Turn OFF/ON and readjusted.
04
- 0057 POD: Connector of left
floatation fan on upper deck
is disconnected.
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0058 POD: Left floatation fan
of upper deck: end of life/
breakage of fan
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0059 POD: Side right fan of
upper deck does not rotate:
breakdown
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
04
- 0060 POD: Left right fan of
upper deck does not rotate:
breakdown
Operation: Upper deck is not used/lifter is lowered
to the lowest position.
How to release: Turn OFF/ON to release
Summary of Contents for imagePRESS 1110
Page 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Page 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Page 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...