3.3 Installation and Service Space
The installation site must provide enough space for unrestricted operation,
maintenance work, and proper ventilation. The machine dimensions are in
diagrams on the following pages. Every attempt should be made to install the
equipment in a room that is large enough for proper servicing and maintenance of
the equipment, and ensure that issues, such as ventilation, odors, and dust
accumulation are not a concern.
IMPORTANT
•
Keep the back of the machine, with all of its doors and access panels open, at
least 31.5” (800 mm) away from a wall.
•
Keep the front and sides of the machine, with all of its doors and access panels
open, at least 19.7” (500 mm) away from a wall.
•
The floor must be level (with no bows) for the stabilization and support of the
machine.
•
The minimum doorway opening that the machine passes through prior to
installation must be at least 36” wide.
•
The minimum elevator depth used to transport the machine prior to installation
must be at least 56”.
•
At least 44 3/4” (1,135 mm) in width is necessary to negotiate turns prior to
installation.
•
The machine cannot be moved once it is in place.