Version 2
imagePRESS C6010 Customer Expectations Document
Page 20
The following illustration shows the relative position of the power outlets and
voltage requirements of each optional accessory item.
IMPORTANT
•
Phase converters and step down transformers are not supported.
•
We recommend an additional standard 115 V/15 A outlet for service tools, such
as a laptop computer or vacuum that may be used when servicing or configuring
the machine.
•
Use only dedicated and properly grounded outlets for the main unit and
imagePRESS Server. It is also strongly suggested to use dedicated and properly
grounded outlets for each optional accessory. Do not use extension cords. The
ground connection serves to provide the internal electronics with a reference
voltage. Faulty or poor ground sources will cause this reference voltage to fall
into a range that no longer serves as a reliable reference voltage. The internal
logic and programming of the imagePRESS C6010 will not perform reliably
because there is an insufficient difference between the internal operating signal
voltages and the poor ground reference signal. A qualified electrician can
measure and provide the ground source that the imagePRESS C6010 or any
computer controlled office equipment requires.
•
Before installation, confirm that all necessary receptacles are available.
•
If the optional Integrated Interface & Stand-A1, which includes a furniture stand,
monitor, keyboard, and mouse, is installed on the imagePRESS Server A1300 or
A2300, an additional 115 V/6 A (NEMA 5-15) receptacle is required for the
monitor.