NOTE
The Puncher Unit-V1, Document Insertion Unit-C1, DADF-R1, Color Image
Reader-H1, Booklet Trimmer-C1, and Paper Deck-A1 do not require any
additional outlets.
The following illustration shows the relative position of the power outlets, voltage
requirements, and dimensions of each optional accessory item.
(Note: Phase converters are not supported.)
IMPORTANT
Canon USA strongly recommends that dedicated and properly grounded outlets
be provided for the devices mentioned above. The ground connection serves to
provide the internal electronics with a reference voltage. Faulty or poor ground
sources will cause this reference voltage to fall into a range that no longer
serves as a reference voltage. The internal logic and programming of the
imagePRESS C7000VP will not perform reliably because there is an insufficient
difference between the internal operating signal voltages and the poor ground
reference signal. A qualified electrician can measure and provide the ground
source that the imagePRESS C7000VP or any computer controlled office
equipment requires.
Before installation, confirm that a dedicated NEMA L21-30 receptacle is
available as needed.
Version 1 imagePRESS C7000VP Customer Expectations Document Page 14