iPF6400S Basic Guide
151
Er
ror M
essa
ge
Me
ssa
ges
r
egar
ding
pr
inti
ng
or
a
djus
tm
ent
Blue platen switch is dirty.
Cause
Corrective Action
The blue Switch on the platen is dirty.
Open the Top Cover and clean the blue Switch on the platen.
(See "Cleaning Inside the Top Cover.")
➔
P.53
Move the blue platen switch No.xx to the right. (xx represents a number)
Cause
Corrective Action
The printer has detected that the blue Switch on the platen
needed in maintenance during printing is set away from the
●
mark.
Set blue platen Switch of the indicated number toward the
●
side.
(See "Setting the Blue Switch on the Platen.")
➔
P.120
Cannot adjust paper feed.
Cause
Corrective Action
The Printhead nozzles are clogged.
Execute
Adj. Quality
again, as follows.
1. Press the
OK
button to clear the error.
2. Print a test pattern to check the nozzles.
(See "Checking for Nozzle Clogging.")
➔
User's Guide
3. Clean the Printhead if the nozzles are clogged.
(See "Cleaning the Printhead.")
➔
P.55
4. Execute
Adj. Quality
again.
(See "Automatic Banding Adjustment.")
➔
P.100
Highly transparent film is loaded that cannot be used for
automatic feed amount adjustment.
Press the
OK
button to clear the error, and then adjust the
feed amount manually.
(See "Manual Banding Adjustment.")
➔
User's Guide
Check printed document.
Cause
Corrective Action
The Printhead nozzles are becoming clogged.
If printing is faint, clean the Printhead.
(See "Cleaning the Printhead.")
➔
P.55
Spectrophotometer Unit not connected.
Cause
Corrective Action
The Spectrophotometer Unit is not installed
correctly.
Turn off the power and reinstall the Spectrophotometer Unit.
Spectrophotometer Sensor not mounted.
Cause
Corrective Action
The Spectrophotometer Sensor to
be loaded into the
Spectrophotometer Carriage is not
installed correctly.
Turn off the power, and reinstall by pushing the two connectors all the way into the
Spectrophotometer Sensor.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit
(option).")
➔
User's Guide