iPF6400S Basic Guide
152
Er
ror M
essa
ge
Me
ssa
ges
r
egar
ding
pr
inti
ng
or
a
djus
tm
ent
Spectrophotometer Unit Calibration white tile error.
Cause
Corrective Action
The White Calibration Tile is not
installed.
Install the White Calibration Tile.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit
(option).")
➔
User's Guide
The White Calibration Tile is dirty.
Remove, clean, and reinstall the White Calibration Tile.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")
➔
P.56
The performance of part of the
Spectrophotometer Sensor may
be impaired.
If this message is still displayed after cleaning the White Calibration Tile, we
recommend adjusting the Spectrophotometer Sensor.
Contact your Canon dealer for more information on adjustment services.
(See "Replacing the Spectrophotometer Sensor of the Spectrophotometer Unit
(option).")
➔
User's Guide
Spectrophotometer Unit eject guide not mounted.
Cause
Corrective Action
The Spectrophotometer Eject Guide is installed incorrectly,
such as being installed askew, or not pushed in all the way.
Make sure that the Spectrophotometer Eject Guide is
loaded in the correct position, push it in all the way, and
press the
OK
button.
There is a foreign object on the Spectrophotometer Eject
Guide.
Remove the foreign object and press the
OK
button.
The performance of part of the Spectrophotometer Unit
may be impaired.
Turn off the printer, wait a while, and then turn it on again.
If the same message is displayed again, contact your
Canon dealer for assistance.
Spectrophotometer Unit Backing plate error.
Cause
Corrective Action
The White/Black Backing Plate is not installed
correctly.
Remove and correctly attach the White/Black Backing Plate, and then
press the
OK
button.
(See "Switching the White/Black Backing Plate (Optional) Color.")
➔
User's Guide
The White/Black Backing Plate is soiled.
Clean the White/Black Backing Plate and then press the
OK
button.
(See "Cleaning the Spectrophotometer Unit (option) Parts.")
➔
P.56
Spectrophotometer Sensor Cover open.
Cause
Corrective Action
The Spectrophotometer Sensor Cover of the
Spectrophotometer Unit is open.
Close the Spectrophotometer Sensor Cover and press the
OK
button.
Spectrophotometer Unit cover open.
Cause
Corrective Action
The Spectrophotometer Unit Cover of the
Spectrophotometer Unit is open.
Close the Spectrophotometer Unit Cover and press the
OK
button.