4
4
4-30
4-30
Parts Replacement and Cleaning > Main Units/Parts > Removing the CIS Unit
Parts Replacement and Cleaning > Main Units/Parts > Removing the CIS Unit
Action to Take after Replacement
MEMO:
The service parts for toner supply unit do not come with a bottle ring. Remove the
bottle ring from the old toner supply unit and attach it to the new one.
The procedure is as follows:
1) Remove the toner bottle set lever.
1 parallel pin
2) Remove the bottle base.
1 screw
1 claw
爪
x1
x1
■
•
•
•
F-4-58
F-4-58
F-4-59
F-4-59
3)Remove the bottle ring.
Removing the CIS Unit
1) Open the platen (ADF/platen board cover).
2) Remove the reader rear cover.(
"Removing the Reader Rear Cover"(page 4-19).
)
3) Remove the reader right.(
"Removing the Reader Right Cover"(page 4-19).
)
4) Remove the right glass retainer.
5) Remove the platen glass.(
"Removing the Platen Glass"(page 4-19).
)
6) Move the belt in the arrow direction and then the CIS unit to the groove position of the
frame.
F-4-60
F-4-60
F-4-61
F-4-61
Summary of Contents for IMAGERUNNER 2530
Page 1: ...9 8 7 6 5 4 3 2 1 imageRUNNER 2530 2525 2520 Series Service Manual...
Page 4: ...Blank Page...
Page 16: ...1 1 Product Overview Product Overview Product Lineup Feature Specifications Name of Parts...
Page 111: ...3 3 Periodical Service Periodical Service Consumable Parts and Cleaning Parts...
Page 159: ...5 5 Adjustment Adjustment Outline Adjustment when replacing parts Image position adjustment...
Page 166: ...6 6 Troubleshooting Troubleshooting Upgrading Targets and Procedure...
Page 171: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code...
Page 186: ...8 8 Service Mode Service Mode Outline Details of Service Mode...
Page 321: ...Service Tools General Circuit Diagram Appendix...