2
2
2-52
2-52
Technology > Fixing System > Controls > Protection features
Technology > Fixing System > Controls > Protection features
Protection features
Code
Description
Error
Clear
E000
Fixing temperature abnormal rise
0001 The temperature detected by the main thermistor does not rise to the
specified value during startup control.
Yes
E001
Fixing unit temperature rise detection
0000 The reading of the main thermistor is 250 deg C or more continuously
for 200 msec.
Yes
0001
The hardware circuit detects overheating of the main or sub thermistor
for 200 msec.
Yes
0002 The reading of the sub thermistor is 295 deg C or more continuously
for 200 msec.
Yes
E002
Fixing unit temperature insufficient rise
0000 1.The reading of the main thermistor is less than 115 deg C
continuously for 400 msec 1.3 sec after it has indicated 100 deg C.
2.The reading of the main thermistor is less than 150 deg C
continuously for 400 msec 1.3 sec after it has indicated 140 deg C.
Yes
E003
Low fixing temperature detection after standby
0000 The reading of the main thermistor is less than 140 deg C continuously
for 400 msec or more.
Yes
E004
Thermistor disconnection detection error
0000
When disconnection is detected with connector (J214) for 30 sec
continuously.
No
E014
Unstable rotation of the Fixing Motor (M2)
0001 Detection is executed every 100 msec after the start of motor rotation;
however, the drive detection signal is absent for 2 sec.
0002
During motor rotation, detection is executed every 100 msec; however,
the drive signal is absent 5 times in sequence.
No
E261
Error in Zero Cross
0000
Zero Cross failed to be detected for 500ms or more while the relay
was ON. * The same condition is detected after the error retry is
performed.
No
Related Service Mode
Error code clear
CLEAR > ENGIN > ERRCLR
•
■
T-2-29
T-2-29
Summary of Contents for IMAGERUNNER 2530
Page 1: ...9 8 7 6 5 4 3 2 1 imageRUNNER 2530 2525 2520 Series Service Manual...
Page 4: ...Blank Page...
Page 16: ...1 1 Product Overview Product Overview Product Lineup Feature Specifications Name of Parts...
Page 111: ...3 3 Periodical Service Periodical Service Consumable Parts and Cleaning Parts...
Page 159: ...5 5 Adjustment Adjustment Outline Adjustment when replacing parts Image position adjustment...
Page 166: ...6 6 Troubleshooting Troubleshooting Upgrading Targets and Procedure...
Page 171: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code...
Page 186: ...8 8 Service Mode Service Mode Outline Details of Service Mode...
Page 321: ...Service Tools General Circuit Diagram Appendix...