Periodic Inspection of the Breaker
26
Periodic Inspection of the Breaker
This machine has a breaker that detects excess current or leakage current.
Be sure to test the breaker once or twice a month using the following procedure.
IMPORTANT
• Make sure that the main power is turned ON, and the machine is neither printing nor scanning before
starting periodic inspection of the breaker.
• If a malfunction occurs after a periodic inspection, contact your service representative.
1
Press the test button located at the bottom left
of this machine.
NOTE
• Push the test button with the tip of the ball-point
pen, etc.
• For details of the location of the breaker when the
Finisher is attached, see “Internal View,” on p. 1-3.
2
The breaker lever automatically goes to OFF
(“
” side). Confirm that the power is cut OFF.
IMPORTANT
• Do not use the test button to turn the power ON
and OFF.
• If the breaker lever does not go to OFF (“
”
side), repeat step 1.
• If the breaker lever does not go to OFF (“
”
side) despite carrying out the above procedure
two or three times, contact your service repre-
sentative.
3
Once you confirmed that the above operation
takes place, press the main power switch to
OFF (“
” side).
E82_US.book Page 26 Tuesday, May 22, 2001 12:11 AM
Summary of Contents for ImageRunner 5000 Series
Page 1: ......
Page 2: ...imageRUNNER 5000 Series User s Guide Series E82_US book Page 1 Tuesday May 22 2001 12 11 AM ...
Page 51: ...E82_US book Page 50 Tuesday May 22 2001 12 11 AM ...
Page 293: ...E82_US book Page 96 Tuesday May 22 2001 12 11 AM ...
Page 411: ...E82_US book Page 14 Tuesday May 22 2001 12 11 AM ...
Page 485: ...E82_US book Page 36 Tuesday May 22 2001 12 11 AM ...
Page 515: ...E82_US book Page 22 Tuesday May 22 2001 12 11 AM ...
Page 521: ...E82_US book Page vi Tuesday May 22 2001 12 11 AM ...
Page 523: ......