2
2
2-161
2-161
Technical Explanation > DCM > Limitations about Import/Export by "Settings/ Registration" > Limitation
Technical Explanation > DCM > Limitations about Import/Export by "Settings/ Registration" > Limitation
■
Limitations on DCM General
• With DCM, stored data in Box, MEAP application, and system option license cannot be
migrated.
• A DCM file exported to the internal HDD is not deleted even when the machine is restarted.
Only 2 files at a maximum are stored in HDD. When there are more than 2 files, the oldest
file are deleted.
• After importing a file, the machine must be restarted. If executing import without restart, NG
is displayed and a file is not imported. This operation is not guaranteed.
• When importing DCM file including "Service Mode Settings" and "Settings/Registration
Basic Information" separately, perform it in the following procedures.
1) Perform the import of the DCM file including "Service Mode Settings" earlier
2) Restart the host machine
3) Import the DCM file including "Settings/Registration Basic Information"
• As include "Service Mode Settings", if the process is not completed within 5 minutes in
the case of export and 15 minutes in the case of import, the item performed at that time is
continued until it ends, but the final result becomes ERROR.
• DCM files to which no password is set when exporting by service mode cannot be loaded
from collective import by remote UI. When assuming to perform collective import by remote
UI, password must be set to data to be exported.
• Following limitations are applied to password for DCM file.
• Character string of software keyboard: 0 to 32 characters
• No password is set when 0 character is entered (The setting in which no password is
set is allowed only export by service mode)
• No space is allowed in the middle of a password
• Password is case sensitive
• At the time of following setting, host matchine does not recognize USB device. The DCM
function is not usable, too.
[Settings/Registration] > [Preferences] > [External Interface] > [USB Settings] > [Use
MEAP Driver for External USB Device] = "On"
Limitations about Import/Export by "Settings/
Registration"
■
Overview
Changing the value of a related service mode item can include items of "Service Mode
Settings" in a DCM file that is to be exported by "Settings/ Registration".
A DCM file exported by "Settings/ Registration" can also be imported by service mode without
using remote UI.
For details of import/export by remote UI, refer to the this machine's e-Manual.
■
Limitation
• An import/export process ends with error while the following specific job is executed.
• Send job
• Forwarding job
• FAX reception job
• IFAX reception job
• If this function is executed with a print job simultaneously, it affects the operation such as;
UI is locked, or a print job is cleared by restart after import. So it requires careful operation.
• A device rejects an import/ export request during shutdown.
• If this function is executed with device information distribution or remote UI import/ export
(Individually) simultaneously, the first coming job takes priority and they are controlled
exclusively.
• If this function is executed with a firmware update by a CDS (Updater) simultaneously, a
firmware update process takes priority, and this function is stopped temporarily by restart.
• When error code is issued, this function ends with error.
• If the display language before import differs from that after import,, a setting value of a text
corrupts in some cases. The character corruption can be solved by changing the display
language to the appropriate one.