A. Power and Plug Requirements
Canon USA Inc. strongly suggests dedicated and properly grounded outlets be
provided for these imageRUNNER ADVANCE.
The imageRUNNER ADVANCE C5255/C5250 Main Unit requires a
dedicated single-phase 120V/20A NEMA 5-20R receptacle for proper
operation
The imageRUNNER ADVANCE C5240A/C5235A Main Unit requires a
dedicated single-phase 120V/15A NEMA 5-15R receptacle for proper
operation.
Table 14 – Power Receptacle
imageRUNNER ADVANCE C5255/C5250
imageRUNNER ADVANCE C5240A/C5235A
NEMA 5-20 Receptacle
NEMA 5-15 Receptacle
IMPORTANT
We recommend an additional standard 120 V/15 A outlet for service tools,
such as a laptop computer or vacuum that may be used when servicing or
configuring the machine.
Use only dedicated and properly grounded outlets for the main unit and
imagePASS or ColorPASS Controllers. Do not use extension cords. The
ground connection serves to provide the internal electronics with a
reference voltage. Faulty or poor ground sources will cause this reference
voltage to fall into a range that no longer serves as a reliable reference
voltage. The internal logic and programming of the imageRUNNER
ADVANCE Series machines will not perform reliably because there is an
insufficient difference between the internal operating signal voltages and
the poor ground reference signal. A qualified electrician can measure and
provide the ground source that the imageRUNNER ADVANCE Series
machines or any computer controlled office equipment requires.
Before installation, confirm that all necessary receptacles are available.
Phase converters and step down transformers are not supported.