Procedure
Detail
Note
Time
Clean
Check
Replace
Perform M5 to M6 at the same time to save time
3
min
Clean
1
min
Visual Check
5
min
Replace
Clean the patch
sensor / Check the
sensor shutter
1.
Remove the ITB Ass’y to see the Patch Sensor
shutter.
2.
Check and clean the Patch Sensor shutter with
lint free towel.
If the patch Sensor shutter is broken, replace it
with new one. Patch registration sensor unit
(
FM1-G546-000)
.
Point;
1.When you clean the patch sensor, do not bend the
Mylar on the right side. It causes smearing image.
2.Check for proper operation of the patch solenoid for
binding/damage to arm solenoid is a part of Patch Drive
Assembly
FM1-N636-000
Clean the Laser slit
Glass[4]
Use the Dust-Blocking glass cleaning tool to clean the
laser glass.
If the pad is worn out, replace it with new one
(
FL2-9476-010
).
1
min
Clean
Main
tenance
Pr
ocess
M5
M6
iR ADV C5500 series Advance Maintenance Guide