Chapter 3
3-3
0003
The lock (normal state) signal remains even when
the ITB drum motor has been stopped (i.e., the lock
(normal state) signal is detected continuously for 2
sec after the ITB drum motor control signal has been
turned OFF).
E020
There is a fault associated with the drum/developer.
For the first 2 digits of detail code xx12 through xxD0,
xx=01: Y
xx=02: M
xx=03: C
xx=04: Bk
xx20
There is a fault/open circuit in the
ATR sensor. The drum unit is not
fitted normally, or is faulty.
The fault can occur as when a new drum unit has
been fitted. It is detected in about 90 to 120 sec after
idle rotation of the developing assembly.
xx24
There is a fault/open circuit in the
SALT sensor.
The fault can occur as when a new drum unit has
been fitted. It is detected during ATR control or in
about 150 sec after idle rotation of the developing
assembly.
xx25
There is a fault/open circuit in the
SALT sensor.
The ITB has deteriorated.
The fault can occur as when a new drum unit has
been fitted. It is detected during ATR control or in
about 150 sec after idle rotation of the developing
assembly.
xx30
There is a fault/open circuit in the
ATR sensor. The setting of the
ATR sensor computation value is
wrong.. The drum unit is not
fitted properly, or is faulty.
The fault can occur as when a new drum unit has
been fitted. It is detected in about 90 to 120 sec after
idle rotation of the developing assembly.
xx34
The sample image fails to be
drawn in ATR control. There is a
fault/open circuit in the SALT
sensor. The drum unit is faulty.
The ITB has deteriorated.
The fault can occur as when a new drum unit has
been fitted. It is detected during ATR control or in
about 150 sec after idle rotation of the developing
assembly.
xx35
There is a fault/open circuit in the
SALT sensor.
The fault can occur as when a new drum unit has
been fitted. It is detached during ATR control or in
about 150 sec after idle rotation of the developing
assembly.
Code
Detail
Description
Timing of detection
Summary of Contents for iR C3200 Series
Page 1: ...Dec 3 2004 Portable Manual iR C3200 Series iR C3220N PRT ...
Page 2: ......
Page 6: ......
Page 10: ......
Page 11: ...Chapter 1 Maintenance and Inspection ...
Page 12: ......
Page 14: ......
Page 22: ...Chapter 1 1 8 ...
Page 23: ...Chapter 2 Standards and Adjustments ...
Page 24: ......
Page 26: ......
Page 40: ...Chapter 2 2 14 ...
Page 41: ...Chapter 3 Error Code ...
Page 42: ......
Page 43: ...Contents Contents 3 1 Error Code Details 3 1 3 1 1 Error Code Details Table 3 1 ...
Page 44: ......
Page 63: ...Chapter 4 User Mode Items ...
Page 64: ......
Page 66: ......
Page 79: ...Chapter 5 Service Mode ...
Page 80: ......
Page 82: ......
Page 121: ...Chapter 6 Outline of Components ...
Page 122: ......
Page 124: ......
Page 134: ...Chapter 6 6 10 F 6 6 PLG1 ELCB1 SP1 H4 H3 H2 H1 H1 H2 LA1 ...
Page 138: ...Chapter 6 6 14 ...
Page 139: ...Chapter 7 System Construction ...
Page 140: ......
Page 142: ......
Page 157: ...Chapter 8 Upgrading ...
Page 158: ......
Page 160: ......
Page 168: ...Chapter 8 8 8 ...
Page 169: ...Dec 3 2004 ...
Page 170: ......