Chapter 7
7-16
3. Flow of Operation
F-7-21
B. Black D-max Control
1. Start-Up Timing
- when the Bk drum unit is replaced with a new one
- during post-rotation executed every 1000 prints
- during execution of calibration (user mode)
2. Particulars of Control
In the presence of a specific condition, the DC controller forms a patch pattern (Notes) of Bk on the ITB.
Thereafter, the DC controller uses the patch image sensor (UN16) to measure the patch density, thereby correcting the developing DC bias of Bk so that the density
will be identical to the target density.
F-7-22
[1] Patch image data
[2] Developing DC bias
[3] Developing cylinder
UN16: patch image sensor
MEMO:
To reduce down-time, the machine forms only one patch on the ITB. If, however, the measured patch density is outside the range of correction, it forms an additional
patch. If the density is still outside the range of correction for a second time, the machine continues until it has formed as many as 4 patches.
Start-up
Patch pattern formation
Patch reading
UN16
DC controller
D-max correction table creation
(Y, M, C)
DC controller
Laser output determination
Laser output
Density
Y3
Y1
Y2
Y8
0
EX: D-max correction table for Y
DC controller
D-CON
[2]
UN16
ITB
Bk
[1]
HVT1
[3]
Summary of Contents for iR C3380 series
Page 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series...
Page 2: ......
Page 6: ......
Page 23: ...Chapter 1 Introduction...
Page 24: ......
Page 26: ......
Page 52: ......
Page 53: ...Chapter 2 Installation...
Page 54: ......
Page 127: ...Chapter 3 Basic Operation...
Page 128: ......
Page 130: ......
Page 136: ......
Page 137: ...Chapter 4 Main Controller...
Page 138: ......
Page 160: ......
Page 161: ...Chapter 5 Original Exposure System...
Page 162: ......
Page 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69...
Page 189: ...Chapter 6 Laser Exposure...
Page 190: ......
Page 192: ......
Page 206: ......
Page 207: ...Chapter 7 Image Formation...
Page 208: ......
Page 256: ......
Page 257: ...Chapter 8 Pickup Feeding System...
Page 258: ......
Page 262: ......
Page 303: ...Chapter 9 Fixing System...
Page 304: ......
Page 306: ......
Page 321: ...Chapter 10 Externals and Controls...
Page 322: ......
Page 326: ......
Page 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled...
Page 337: ...Chapter 10 10 11 F 10 11...
Page 359: ...Chapter 11 MEAP...
Page 360: ......
Page 362: ......
Page 401: ...Chapter 12 RDS...
Page 402: ......
Page 404: ......
Page 411: ...Chapter 13 Maintenance and Inspection...
Page 412: ......
Page 414: ......
Page 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4...
Page 421: ...Chapter 14 Standards and Adjustments...
Page 422: ......
Page 424: ......
Page 431: ...Chapter 15 Correcting Faulty Images...
Page 432: ......
Page 434: ......
Page 459: ...Chapter 16 Self Diagnosis...
Page 460: ......
Page 462: ......
Page 481: ...Chapter 17 Service Mode...
Page 482: ......
Page 484: ......
Page 571: ...Chapter 18 Upgrading...
Page 572: ......
Page 574: ......
Page 603: ...Chapter 19 Service Tools...
Page 604: ......
Page 606: ......
Page 609: ...Aug 29 2006...
Page 610: ......