Chapter 16
16-9
C001 HDD access error
Format and re-install the whole system, Replace the
HDD, Replace the main controller PCB.
E731
UFR PCB error
3000 The UFR PCB fails to be recognized at start-up.
Check on connection of the UFR PCB , Replace the
UFR PCB , Replace the main controller PCB
3001 The UFR PCB fails to be initialized at start-up.
3002 Rambus fails to be initialized.
3015 Image data fails to be sent to the tip on the main controller PCB (main).
Turn OFF and back ON the main power, Replace the
UFR PCB , Replace the main controller PCB
E732
Reader communication error
0001 DDI-S communication error
Check on connection between the reader controller
PCB and the main controller PCB, Check on the reader
power supply
E733
Printer communication error
0000 The printer fails to be detected at start-up.
Check on connection between the DC controller PCB
and the main controller PCB, Check on the printer
power supply
0001 DDI-P communication error
E740
Abnormality of the Ethernet board
0002 Incorrect MAC address is detected at start-up.
Replace the Ethernet board , Replace the main
controller PCB (sub LAN-bar)
0003 Incorrect network ID is detected at start-up.
E743
DDI communication error
0001 The reader controller PCB detects communication error between the main controller
PCB and the reader controller PCB.
Disconnect and then connect the reader
communication cable connector, Replace the reader
controller PCB, Replace the main controller PCB
E744
Language file/BootROM error
0001 Language version and Bootable version in the HDD differ.
Upgrade the version of the Language file
0002 The language size in the HDD is too large.
0003 Language in Config.txt in the HDD that should be switched fails to be found.
Switch to the language in the HDD cannot be done.
0004 Switch to the language in the HDD cannot be done.
1000 The BootROM for other model is connected.
Replace the BootROM
1001 System version and BootROM version do not match.
Replace the BootROM, Upgrade the system version
2000 Incorrect engine ID is detected.
Re-install the system
4000 Incorrect DC controller PCB is detected.
Upgrade the DC controller PCB version
E745
Token ring board error
0001 Initialization of the token ring driver using PCI ends in failure.
Check on connection of the token ring board, Replace
the token ring board
0002 MAC address is abnormal when the token ring driver is initialized.
0003 Board information acquisition/setting is abnormal when the token ring board is
initialized.
0004 Connection error when the token ring driver starts up.
Check on connection of the cable, Check on power
supply of the MAU
E746
Option board error
0003 The UFR PCB for other model is detected at start-up.
Replace with an appropriate UFR PCB
0004 The main controller PCB (sub) for other model is detected at start-up.
Replace with an appropriate main controller PCB (sub)
E747
Main controller PCB error (Image processing ASIC or memory control/communication control ASIC)
XXXX IC12 (image processing ASIC) or IC23 (memory control/communication control ASIC,
CPU) on the main controller PCB is abnormal (such as image data transfer error)
Turn OFF and back ON the main power, Replace the
main controller PCB (main)
E747
Main controller PCB error
0000-1217 An error occurs in the main controller PCB (Main).
Turn the main power off and turn it back on.
Replace the main controller PCB (Main).
2000-3D00 An error occurs in the communication with the main controller PCB (Sub PE).
Disconnect and connect the main controller PCB (Sub
PE), or replace it.
Replace the main controller PCB (Main).
3F00,3F02 When Unmounting of the main controller PCB (Sub PE) is detected.
Disconnect and connect the main controller PCB (Sub
PE), or replace it.
6000-7D00 An error occurs in the communication with the main controller PCB (Sub R)
Disconnect and connect the main controller PCB (Sub
R), or replace it.
Replace the main controller PCB (Main).
7F00 When unmounting of the main controller PCB (Sub R) is detected.
Disconnect and connect the main controller PCB (Sub
R), or replace it.
8000-9C00 A error occurs in the communication with the open interface PCB.
Disconnect and connect the open interface PCB, or
replace it.
Replace the main controller PCB (Main).
9F00 When unmounting of the main controller PCB (Sub R) is detected.
Disconnect and connect the main controller PCB (Sub
R), or replace it.
C000-DC00 An error occurs in the communication with the main controller PCB (Sub SJ).
Disconnect and connect the main controller PCB (Sub
SJ), or replace it.
Replace the main controller PCB (Main).
DF00 When unmounting of the main controller PCB (Sub SJ) is detected. Disconnect and connect the main controller PCB (Sub
SJ), or replace it.
FF00 Incorrect main controller PCB (Sub SJ/PE/R) or incorrect open interface PCB is
detected.
Replace with an appropriate main controller PCB (Sub
SJ/PE/R) or open interface PCB.
Code
Main Cause/Detail of Detection
Countermeasures
Summary of Contents for iR C3380 series
Page 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series...
Page 2: ......
Page 6: ......
Page 23: ...Chapter 1 Introduction...
Page 24: ......
Page 26: ......
Page 52: ......
Page 53: ...Chapter 2 Installation...
Page 54: ......
Page 127: ...Chapter 3 Basic Operation...
Page 128: ......
Page 130: ......
Page 136: ......
Page 137: ...Chapter 4 Main Controller...
Page 138: ......
Page 160: ......
Page 161: ...Chapter 5 Original Exposure System...
Page 162: ......
Page 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69...
Page 189: ...Chapter 6 Laser Exposure...
Page 190: ......
Page 192: ......
Page 206: ......
Page 207: ...Chapter 7 Image Formation...
Page 208: ......
Page 256: ......
Page 257: ...Chapter 8 Pickup Feeding System...
Page 258: ......
Page 262: ......
Page 303: ...Chapter 9 Fixing System...
Page 304: ......
Page 306: ......
Page 321: ...Chapter 10 Externals and Controls...
Page 322: ......
Page 326: ......
Page 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled...
Page 337: ...Chapter 10 10 11 F 10 11...
Page 359: ...Chapter 11 MEAP...
Page 360: ......
Page 362: ......
Page 401: ...Chapter 12 RDS...
Page 402: ......
Page 404: ......
Page 411: ...Chapter 13 Maintenance and Inspection...
Page 412: ......
Page 414: ......
Page 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4...
Page 421: ...Chapter 14 Standards and Adjustments...
Page 422: ......
Page 424: ......
Page 431: ...Chapter 15 Correcting Faulty Images...
Page 432: ......
Page 434: ......
Page 459: ...Chapter 16 Self Diagnosis...
Page 460: ......
Page 462: ......
Page 481: ...Chapter 17 Service Mode...
Page 482: ......
Page 484: ......
Page 571: ...Chapter 18 Upgrading...
Page 572: ......
Page 574: ......
Page 603: ...Chapter 19 Service Tools...
Page 604: ......
Page 606: ......
Page 609: ...Aug 29 2006...
Page 610: ......