Chapter 17
17-62
CNT-DISP
Used to select whether to display serial number when counter check key is pressed.
0: Display serial number.
1: Don't display serial number.
2
NW-SCAN
Used to select whether to permit network scan function
0: Don't permit
1: Permit (Invalid when UFR board or open interface board isn't connected.)
2
HDCR-DSP
Selection of clear method in hard disk all data erasure mode
This selects the method clearing the data in the hard disk all data erasure mode.
Settings
1: Cleared once using 0 (null) data.
2: Cleared once using random data.
3: Cleared 3 times using random data.
[Factory setting/value after clearing RAM: 1]
MEMO:
Hard disk all data erasure function
This function overwrites the 0 (null) data and random data in the file data area on the hard disk at the logical timing of
erasing the files (the timing at which the control information data is erased), and it thereby erases all the data on the hard
disk.
2
JOB-INVL
Used to set job interval during interrupt.
0: Standard setting (Output next job continuously during interrupt copy job.)
1: Start output of next job after last sheet of interrupt copy job has been delivered.
2: Start output of next job after last sheet of any job has been delivered.
2
P-CRG-LF
Used to select operation performed when drum unit has reached end of service life.
0: Don't stop
1: Stop
2
PCL-COPY
PCL COPIES command binder control mode
The PCL COPIES command control method differs between the PCLs made in-house and the PCLs made by sources
outside the company, and it is for the purpose of standardizing the operations of both kinds of PCLs that this mode has
been provided.
Settings
0: Control is exercised on a page by page basis as per the COPIES command value specified on the page concerned.
1: The COPIES command value specified on page 1 is treated as the binding number, and the COPIES command values
on the next and subsequent pages are canceled. (This is set only when the sort mode is established. In a non-sorting
mode, the same control is exercised as when "0" is set.)
2 to 65535: Spare
[Factory setting/value after clearing RAM: 0]
"0" is the control method applicable to in-house PCLs, and by setting the item to "1", the same control method as used
with PCLs made by sources outside the company is exercised.
2
PRJOB-CP
Setting for selecting whether to output the count pulses during reception printing and report printing
This selects whether to output the count pulse notice for each page during reception printing and report printing to the
charge management system when a charge management system (coin vendor or control card made by another company)
is used.
Settings
0: The count pulses are not output.
1: The count pulses are output.
[Factory setting/value after clearing RAM: 0]
2
DPT-ID-7
Registering a department ID and inputting a 7-digit code for authentication.
Setting Values
0: As before [Factory default/After RAM clear]
1: Inputting a 7-digit code
Reference Infomation Support for Siemens
2
RUI-RJT
Disconnecting the HTTP port when three authentication failures from RUI are recognized.
Setting Values
0: Invalid [Factory default/After RAM clear]
1: Valid
Reference Information Support for Siemens
2
SND-RATE
Sets compression rate when compression rate in SEND is selected 'High'.
Setting values
0: Compression rate 1/16
1: Compression rate 1/20
2: Compression rate 1/24
[Factory settings and after RAM clear: 0]
2
CTM-S06
Setting for deleting password from export file of file transmission address
Settings
0: The password is not deleted.
1: The password is deleted.
[Factory setting/value after clearing RAM: 0]
When this item is set to "1," the password of the file transmission destination is deleted from the export file when the
address book data has been exported from the remote UI. (This is to prevent information leaks.)
2
FREG-SW
Selection of whether to display the free register area of the MEAP counter (for SEND)
Settings
0: The free register area is not displayed.
1: The free register area is displayed.
[Factory setting/value after clearing RAM: 0]
Memo:
- This is not used with normal servicing. (It is used for analyzing trouble causes).
- To use it, the instructions given by the quality support division must be followed.
2
COPIER>OPTION>USER
Specification selection related to user mode
Sub item
Description
level.
Summary of Contents for iR C3380 series
Page 1: ...Aug 29 2006 Service Manual iR C3380 2880 Series...
Page 2: ......
Page 6: ......
Page 23: ...Chapter 1 Introduction...
Page 24: ......
Page 26: ......
Page 52: ......
Page 53: ...Chapter 2 Installation...
Page 54: ......
Page 127: ...Chapter 3 Basic Operation...
Page 128: ......
Page 130: ......
Page 136: ......
Page 137: ...Chapter 4 Main Controller...
Page 138: ......
Page 160: ......
Page 161: ...Chapter 5 Original Exposure System...
Page 162: ......
Page 188: ...Chapter 5 5 24 F 5 68 4 Remove the original sensor 2 hook 1 F 5 69...
Page 189: ...Chapter 6 Laser Exposure...
Page 190: ......
Page 192: ......
Page 206: ......
Page 207: ...Chapter 7 Image Formation...
Page 208: ......
Page 256: ......
Page 257: ...Chapter 8 Pickup Feeding System...
Page 258: ......
Page 262: ......
Page 303: ...Chapter 9 Fixing System...
Page 304: ......
Page 306: ......
Page 321: ...Chapter 10 Externals and Controls...
Page 322: ......
Page 326: ......
Page 336: ...Chapter 10 10 10 F 10 10 2 Remove the check mark from SNMP Status Enabled...
Page 337: ...Chapter 10 10 11 F 10 11...
Page 359: ...Chapter 11 MEAP...
Page 360: ......
Page 362: ......
Page 401: ...Chapter 12 RDS...
Page 402: ......
Page 404: ......
Page 411: ...Chapter 13 Maintenance and Inspection...
Page 412: ......
Page 414: ......
Page 416: ...Chapter 13 13 2 F 13 1 8 9 1 2 3 3 5 6 7 10 11 12 13 14 4...
Page 421: ...Chapter 14 Standards and Adjustments...
Page 422: ......
Page 424: ......
Page 431: ...Chapter 15 Correcting Faulty Images...
Page 432: ......
Page 434: ......
Page 459: ...Chapter 16 Self Diagnosis...
Page 460: ......
Page 462: ......
Page 481: ...Chapter 17 Service Mode...
Page 482: ......
Page 484: ......
Page 571: ...Chapter 18 Upgrading...
Page 572: ......
Page 574: ......
Page 603: ...Chapter 19 Service Tools...
Page 604: ......
Page 606: ......
Page 609: ...Aug 29 2006...
Page 610: ......