COPYRIGHT © 2002 CANON INC.
2000 2000 2000 2000
CANON iR1200/iR1300 Series REV. 0 AUG. 2002
6-5
CHAPTER 6 MAINTENANCE AND INSPECTION
4.3.2 Cassette Pickup Roller
Clean it with a cloth moistened with water (and wrung well). If the dirt is excessive, use
alcohol with lint-free paper thereafter, be sure to dry wipe it with a cloth or lint-free paper.
4.3.3 Manual Feed Pickup Roller
Dry wipe it with a cloth moistened with water (and wrung well). If the dirt is excessive,
use alcohol with lint-free paper thereafter, be sure to dry wipe it with a cloth or lint-free pa-
per.
4.3.4 Separation Pad
Dry wipe it with lint-free paper.
4.3.5 Registration Roller
Clean it with a cloth moistened with water (and wrung well). If the dirt is excessive, use
alcohol with lint-free paper thereafter, use a cloth or lint-free paper.
4.3.6 Transfer Guide
Clean it with a cloth moistened with water (and wrung well) thereafter, dry wipe it with a
cloth or lint-free paper.
4.3.7 Transfer Charging Roller
As a rule, do not touch or clean it. However, if cleaning proves necessary as when the
cause of an image fault is the transfer roller, clean it while taking care not to handle the
roller or not to subject it to solvent or oils.
Use lint-free paper and dry wipe it. Do not use water or solvent. During cleaning, take
care not to impose force on the rubber area of the transfer charging roller.
4.3.8 Separation Static Eliminator
Clean it with a blower brush.
4.3.9 Paper Path
Dry wipe it with lint-free paper.
4.3.10 Fixing Inlet Guide
Use alcohol with a soft cloth.
4.3.11 Fixing Pressure Roller
If dirt cannot be removed by executing fixing pressure roller cleaning from the Additional
Functions menu, use alcohol and a soft cloth.