CHAPTER 7 TROUBLESHOOTING
E002
000
During printing, the main thermistor detects 0°C/32°F or lower for
1 sec or more continuously.
About 10 sec or later after power-on/start of printing, the main
thermistor detects less than 120°C/248°F for 1 sec or more con-
tinuously.
After power-on/start of printing, the reading of the main thermistor
does not reach the target value -15°C/11°F or higher within 75 sec.
001
About 10 sec or later after the heater is supplied with power, the
sub thermistor detects less than 75°C/167°F for 2 sec or more con-
tinuously.
Main cause
The fixing film unit is faulty (main thermistor fault, sub thermistor fault,
thermal fuse blow, fixing heater fault). The power supply PCB is faulty. The
DC controller PCB is faulty.
Action
See the descriptions for E003.
E003
During printing, the main thermistor detects less than 120°C/248°F for 1
sec or more continuously.
Main cause
The fixing film unit is faulty (main thermistor fault, thermal fuse blow, fix-
ing heater fault). The power supply PCB is faulty. The DC controller PCB
is faulty.
Action
1. Malfunction
Turn off the power; wait for 10 min, and turn on the power. Is the problem
corrected?
YES: End.
2. Wiring
Is the wiring from the DC controller PCB to the fixing film unit normal?
NO:
Correct the wiring.
3. Fixing film unit
Try replacing the fixing film unit. Is the problem corrected?
YES: End.
4. Power supply PCB, DC controller PCB
Try replacing the power supply PCB. Is the problem corrected?
YES: End.
NO:
Replace the DC controller PCB.