COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 3 IMAGE PROCESSING SYSTEM
3-13 R
4.2.2 Points to Note When Replacing the CCD Unit
Execute ‘CCD auto adjustment’ and
‘edge gain correction position auto adjust-
ment’ in service mode; then, record the up-
dated CCD adjustment data on the service
label.
1) COPIER>FUNCTION>
CCD>CCD-ADJ
CCD Auto Adjustment
2) COPIER>FUNCTION>
CCD>EGGN-POS
Edge Gain Correction Auto
Adjustment
3) all items under
COPIER>ADJUST>CCD
CCD Adjustment Data