Interval
Description
WUP1 (warm-up 1)
Supplies power to the heater at 65% for a specific period of time (400
msec).
WUP2 (warm-up 2)
Controls by switching with in the range between 65% and 100% every 300
msec until the reading is 200°C. (The rate is determined in relation to the
increase in temperature for each specific period of time.)
WUP3 (warm-up 3)
Executes temperature adjustment to 200°C for a specific period of time (10
sec).
INTR (jam check)
Makes a power-on jam check when the power is turned on.
STBY (standby)
Keeps the machine at rest from when WUP3 ends to the Start key is pressed
or until the power switch is turned off.
T02-103-01
Summary of Contents for iR2200 Series
Page 8: ......
Page 12: ......
Page 30: ......
Page 32: ......
Page 54: ......
Page 86: ......
Page 90: ......
Page 94: ......
Page 96: ......
Page 124: ......
Page 142: ......
Page 152: ......
Page 160: ......
Page 168: ......
Page 178: ......
Page 180: ......
Page 222: ......
Page 224: ......
Page 278: ......
Page 280: ......
Page 298: ......
Page 300: ......
Page 324: ......
Page 368: ......
Page 386: ......
Page 388: ......
Page 404: ......
Page 414: ......
Page 416: ......
Page 422: ......
Page 424: ......
Page 434: ......
Page 436: ......
Page 440: ......
Page 468: ......
Page 473: ......
Page 550: ......
Page 552: ......
Page 658: ......
Page 704: ......
Page 706: ......
Page 754: ......
Page 756: ......
Page 760: ......