CHAPTER 5 PICK-UP/FEEDING SYSTEM
5-43 P
1) Remove the cassette.
2) Remove the two screws [1], and detach
the horizontal registration base assem-
bly [2].
F05-901-16
3) Loosen the screw [1], and adjust the
horizontal registration plate [2].
When making adjustments, try to match
the arrow [3] against the index (each
graduation being about 1 mm).
F05-901-17
[1]
[2]
[2]
[1]
[3]