CHAPTER 4 TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
4-28 T
4 Troubleshooting Malfunctions
4.1 Power Supply System
4.1.1 The AC power is absent.
1. Initial checks
[1] Is the power plug connected to the power outlet?
[2] Is the rated AC voltage present at the power outlet?
[3] Has the leakage breaker gone ON?
2. Switch PCB, Wiring, Connector
Is the resistance 0
Ω
when the switch is turned on and
∞Ω
when it is turned
off?
NO:
Replace the switch PCB.
YES: Check the AC power line (power cord, leakage breaker, switch
PCB, main power supply PCB (J6)) for poor wiring (i.e., electrical
continuity); check the connectors for poor contact.