CHAPTER 6 SELF DIAGNOSIS
6-7 T
E010
0000
After the main motor drive signal is generated, the clock signal does to ar-
rive within 1.3 sec.
Main cause
The main motor (M2) is faulty. the DC controller PCB is faulty.
Action
1. Connector
Is the connector of the main motor connected?
NO:
Connect the connector.
2. Main power supply PCB
Is the drive voltage (24 V) of the main motor supplied by the main power
supply PCB?
Main power supply PCB: between J202-1 (24VU1-SW) and J202-2
(OVU1)
NO:
Replace the main power supply PCB.
3. Main controller (M2), DC controller PCB
Press the Start key. Is the lock signal of the main motor present at the con-
nector J308 on the DC controller PCB?
Lock signal: J318-A10 (MM_LOCK)
YES: Replace the main motor.
NO:
Check the wiring; if normal, replace the DC controller PCB.
Summary of Contents for iR2200 Series
Page 8: ......
Page 12: ......
Page 30: ......
Page 32: ......
Page 54: ......
Page 86: ......
Page 90: ......
Page 94: ......
Page 96: ......
Page 124: ......
Page 142: ......
Page 152: ......
Page 160: ......
Page 168: ......
Page 178: ......
Page 180: ......
Page 222: ......
Page 224: ......
Page 278: ......
Page 280: ......
Page 298: ......
Page 300: ......
Page 324: ......
Page 368: ......
Page 386: ......
Page 388: ......
Page 404: ......
Page 414: ......
Page 416: ......
Page 422: ......
Page 424: ......
Page 434: ......
Page 436: ......
Page 440: ......
Page 468: ......
Page 473: ......
Page 550: ......
Page 552: ......
Page 658: ......
Page 704: ......
Page 706: ......
Page 754: ......
Page 756: ......
Page 760: ......