CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 6 SELF DIAGNOSIS
6-28 T
E713
0000
The communication with the finisher is not resumed 3 sec or more after it is
disrupted.
Main cause
The connector has poor connection. The option power supply PCB is faulty.
The finisher controller PCB is faulty. The DC controller PCB is faulty.
Action
1. Connector
Is the wiring between the finisher controller PCB and the options power
supply PCB and between the options power supply PCB and the DC con-
troller PCB normal?
NO:
Correct the wiring.
2. Options power supply PCB
Is the voltage between HJ701-6 (+) and J701-7 (-) on the options power
supply PCB about 24 V?
NO:
Replace the options power supply PCB.
3. Finisher controller PCB, DC controller PCB
Try replacing the finisher controller PCB. Is the problem corrected?
YES: End.
NO:
Replace the DC controller PCB.
Summary of Contents for iR2200 Series
Page 8: ......
Page 12: ......
Page 30: ......
Page 32: ......
Page 54: ......
Page 86: ......
Page 90: ......
Page 94: ......
Page 96: ......
Page 124: ......
Page 142: ......
Page 152: ......
Page 160: ......
Page 168: ......
Page 178: ......
Page 180: ......
Page 222: ......
Page 224: ......
Page 278: ......
Page 280: ......
Page 298: ......
Page 300: ......
Page 324: ......
Page 368: ......
Page 386: ......
Page 388: ......
Page 404: ......
Page 414: ......
Page 416: ......
Page 422: ......
Page 424: ......
Page 434: ......
Page 436: ......
Page 440: ......
Page 468: ......
Page 473: ......
Page 550: ......
Page 552: ......
Page 658: ......
Page 704: ......
Page 706: ......
Page 754: ......
Page 756: ......
Page 760: ......