COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 6 SELF DIAGNOSIS
6-30 T
E719
0001
The communication between the Card Reader-C1 or the coin vendor and
the main controller PCB is disrupted.
Main cause
The wiring is faulty (short circuit, open circuit). The Card Reader-C1 is
faulty. The coin vendor is faulty. The main controller PCB is faulty.
Caution
To clear the error, execute the following in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Action
1. Connector
Is the Cad Reader-C1 or the coin vendor connected securely?
NO:
Connect it securely.
2. Coin vendor, Main controller PCB
Try replacing the Card Reader-C1 or the coin vendor. Is the problem cor-
rected?
YES: End.
NO:
Replace the main controller PCB.
E732
0001
A fault is detected by the main controller PCB in the communication be-
tween reader controller PCB and the main controller PCB.
Main cause
The connector has poor connection. The reader controller PCB is faulty.
Action
1. Connector, Reader controller PCB
Is the connection between the connector J1014 on the main controller PCB
and the connector J409 on the reader controller PCB normal?
NO:
Correct the connection.
YES: Replace the reader controller PCB.
Summary of Contents for iR2200 Series
Page 8: ......
Page 12: ......
Page 30: ......
Page 32: ......
Page 54: ......
Page 86: ......
Page 90: ......
Page 94: ......
Page 96: ......
Page 124: ......
Page 142: ......
Page 152: ......
Page 160: ......
Page 168: ......
Page 178: ......
Page 180: ......
Page 222: ......
Page 224: ......
Page 278: ......
Page 280: ......
Page 298: ......
Page 300: ......
Page 324: ......
Page 368: ......
Page 386: ......
Page 388: ......
Page 404: ......
Page 414: ......
Page 416: ......
Page 422: ......
Page 424: ......
Page 434: ......
Page 436: ......
Page 440: ......
Page 468: ......
Page 473: ......
Page 550: ......
Page 552: ......
Page 658: ......
Page 704: ......
Page 706: ......
Page 754: ......
Page 756: ......
Page 760: ......