CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-32
4.7 Adjusting the Pressure of the Separation Roller of the
Manual Feed Tray
If double feeding or pickup failure occurs during pickup, adjust the position of the pres-
sure spring of the separation roller.
1) Remove the right upper cover.
2) Remove the upper guide [1].
F02-407-01
•
If double feeding occurs, remove the mounting screw [2], and lower the mounting base
[3]; then, tighten the mounting screw [2] in hole A.
•
If pickup failure occurs, remove the mounting screw [2], and raise the mounting base
[3]; then, tighten the mounting screw [3] in hole B.
F02-407-02
[1]
[2]
[3]
hole A
hole B