COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 4 IMAGE FORMATION SYSTEM
4-24 P
3.4.2 Controlling the Output to Suit the Environment (fuzzy control)
The pre-transfer charging current is optimized in relation to the site conditions (i.e., base
on the data from the environment sensor).
F04-304-02
COPIER>OPTION>BODY>FUZZY (turning on/off fuzzy control)
0:
fuzzy control ON (default)
1:
low humidity mode (uses a lower-than-standard pre-transfer charging
current)
2:
normal humidity mode
3:
high humidity mode (use higher-than-standard pre-transfer charging
current)
Setting it to ‘1’ through ‘3’ will make the control independent of the read-
ing from the environment sensor.
Low humidity
¬
®
High humidity
Pre-tr
ansf
er
current
-10
-260