COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 5 PICK-UP/FEEDING SYSTEM
5-41 P
•
The cassette heater (H4) used for the 100V model operates as follows, assuming that the
environment switch (SW3) remains on:
ON
ON
ON
OFF
ON
ON
OFF
OFF
Cassette heater
switch (SW4)
Cassette heater (H4)
OFF
OFF
Standby/front
cover open
During printing
OFF
OFF
In power save
mode
ON
ON
OFF
OFF
Main power
switch (SW1)
T05-700-02
T05-700-01
•
The cassette heater (H4) used for the 230V model operates as follows, assuming that the
environment switch (SW3) remains on:
ON
ON
ON
ON
ON
ON
OFF
OFF
Cassette heater
switch (SW4)
Cassette heater (H4)
OFF
OFF
Standby/front
cover open
During printing
OFF
ON
In power save
mode
ON
ON
OFF
ON
Main power switch
(SW1) OFF