COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 5 PICK UP/FEEDING SYSTEM
5-62 P
2) While keeping the lifter motor M20
(M21) [3] to the right, tighten the screw
[4] temporarily.
F05-902-22
3) Set the cassette 3 (cassette 4) in the ma-
chine without paper.
4) Check to make sure that the lifter drive
gear [5] is engaged with the lifter motor
gear [6] from the right side of the ma-
chine; then, check also to make sure
that the lifter drive gear is fully away
from the lifter gear when the release
button [7] of the cassette 3 (cassette 4)
is pressed halfway.
The expression “pressing the
release button halfway” means
the following:
• The separation roller moves
down.
• The cassette is about to slide
out.
F05-902-23
5) If the filter drive gear is not fully away
from the lifter motor gear, move the left
motor M20 (M21) [3] to the left, and
press the release button halfway once
again to make a check.
F05-902-24
[3]
[4]
[3]
[5]
[6]
[7]