CHAPTER 5 PICK UP/FEEDING SYSTEM
5-79 P
3) Remove the two mounting screws [4],
and detach the duplex feeding fan [5].
Be sure that the arrow indicat-
ing the direction of air is as in-
dicated when mounting the du-
plex feeldng fan.
F05-906-27
9.6.17 Mounting the Reversing Flapper Solenoid
1) Adjust the position of the solenoid us-
ing two screws [2] so that the drive le-
ver [1] is fully pushed when the sole-
noid turns on (i.e., the plunger is
drawn).
F05-906-28
[5]
[4]
[1]