CHAPTER 6 FIXING SYSTEM
6-42 P
4.8 Fixing Assembly Inlet Guide Assembly
4.8.1 Adjusting the Position of the Fixing Assembly Inlet Guide Solenoid
(SL1)
Adjust the position of the solenoid using the two screws [1] so that the guide is as indi-
cated when the solenoid turns on.
F06-408-01
4.8.2 Adjusting the Position of the Fixing Assembly Inlet Guide
•
Points to Note When Making Adjustments in the Field
1. The inlet guide must be positioned as indicated.
2. The inlet guide must shift down when the solenoid (SL1) turns on .
3. The height of the inlet guide must be such that the difference between front and rear is
0.5 mm or less.
4. The height of the inlet guide must be adjusted by loosening the fixing screw on the
height adjusting support plate.
If the inlet guide base is removed, the position of the inlet guide will have
to be adjusted. Do not loosen the mounting screw on the inlet guide base in
the field. Otherwise, be sure to adjust it with reference to the index on the
fixing assembly base.
3.2mm
Upper roller
Lower roller
Solenoid
Inlet guide
9.5mm
12.7mm
[1]