COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 7 EXTERNALS AND CONTROLS
7-38 P
[1]
[2]
[9]
[3]
[6]
[8]
[10]
[7]
[4]
[5]
[8]
[8]
[8]
[1]
[1]
[4]
[3]
[2]
[5]
[6]
[7]
[7]
[8]
[6]
5.6.3 Main Motor Drive Assembly
1) Loosen the belt tensioner [1], and de-
tach the main motor belt [2].
2) Loosen the screw [3] to release the belt
tensioner [4]; then, detach the belt [5].
3) Remove the screw [6], and detach the
fixing member [7].
4) Remove the five screws [8], and discon-
nect the connector [9]; then, detach the
main motor drive assembly [10].
F07-506-04
5.6.4 Manual Feed Pickup Drive Assembly
1) Remove the main controller box.
2) Remove the two screws [1], and detach
the scanner fan duct [2].
3) Loosen the screw [3] to release the belt
tensioner [4], and detach the belt [5].
F07-506-05
4) Remove the four screws [6], and dis-
connect the three connectors [7]; then,
detach the manual feed pickup drive as-
sembly [8].
F07-506-06