CHAPTER 9 SHIFT TRAY
9-10 P
6.1 Removing the Shift Tray Driver PCB
1) Remove the shift tray from the machine.
2) Release the two retaining claws [1], and
detach the cable retaining plate [2].
F09-601-01
3) Remove the two screws [3], and detach
the two limit sensors [4] and the two
grounding wires.
4) Free the cable of the limit sensor from
the cable clamp [5], and disconnect the
connector [6].
F09-601-02
[1]
[2]
[3]
[4]
[4]
[5]
[6]