COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 3 STANDARDS AND ADJUSTMENTS
3-37 T
8.5 Conversion Table for the Potential Control System
Control[V]
Primary[
µ
A]
Developing bias[V] Pre-transfer[
µ
A]
Transfer[
µ
A]
Separation[
µ
A]
3.00
1,400
0
0
440
100
3.05
1,391
3
-2
437
96
3.10
1,382
7
-4
434
92
3.15
1,373
11
-6
431
88
3.20
1,365
15
-8
429
85
3.25
1,356
18
-10
426
81
3.30
1,347
22
-12
426
77
3.35
1,338
26
-14
420
73
3.40
1,330
30
-16
418
70
3.45
1,321
33
-18
415
66
3.50
1,312
37
-20
412
62
3.55
1,303
41
-22
409
58
3.60
1,295
45
-24
407
55
3.65
1,286
48
-26
404
51
3.70
1,277
52
-28
401
47
3.75
1,268
56
-30
398
43
3.80
1,260
60
-33
396
40
3.85
1,251
63
-35
393
36
3.90
1,242
67
-37
390
32
3.95
1,233
71
-39
387
28
4.00
1,225
75
-41
385
25
4.05
1,216
78
-43
382
21
4.10
1,207
82
-45
379
17
4.15
1,198
86
-47
376
13
4.20
1,190
90
-49
374
10
4.25
1,181
93
-51
371
6
4.30
1,172
97
-53
368
2
4.35
1,163
101
-55
365
-1
4.40
1,155
105
-57
363
-5
4.45
1,146
108
-59
360
-8
4.50
1,137
112
-61
357
-12
4.55
1,128
116
-63
354
-16
4.60
1,120
120
-66
352
-20
4.65
1,111
123
-68
349
-23
4.70
1,102
127
-70
346
-27
4.75
1,093
131
-72
343
-31
4.80
1,085
135
-74
341
-35
4.85
1,076
138
-76
338
-38
4.90
1,067
142
-78
335
-42
4.95
1,058
146
-80
332
-46