CHAPTER 5 SERVICE MODE
5-85 T
SIZE-DET
Use it to turn on/off the original size detection mechanism.
Settings
0: ON (default), 1: OFF
Caution
After making the setting, be sure to turn off and then on the main power
switch.
W-TONER
Use it to turn on/off the waste toner case full message.
•
When OFF (no warning) is selected, the message will appear only when
service mode is started.
Settings
0: OFF (no warning issued; default), 1: ON (warning issued)
COUNTER1
Use it to indicate the type of soft counter of the control panel.
Caution
The type of soft counter 1 cannot be changed.
Settings
101: total 1 (default: fixed to 101; see T05-601-01)
COUNTER2
Use it to change the type of soft counter 2 of the control panel to suit the
needs of the user or the dealer.
Settings
000 to 804 (T05-601-01); default: 000 for 100-V model, 103 for 120/230-
V model
COUNTER3
Use it to change the type of soft counter 3 of the control panel to suit the
needs of the user or the dealer.
Settings
000 to 804 (T05-601-01); default: 000 for 100-V model, 203 for 120/230-
V model
COUNTER4
Use it to change the type of soft counter 4 of the control panel to suit the
needs of the user or the dealer.
Settings
000 to 804 (T05-601-091); default: 000 for 100-V model, 203 for 120/
230-V model
COUNTER5
Use it to change the type of soft counter 5 of the control panel to suit the
needs of the user or the dealer.
Settings
000 to 804 (T05-601-01; default, 000)
COUNTER6
Use it to change the type of soft counter 6 of the control panel to suit the
needs of the user or the dealer.
Settings
000 to 804 (T05-601-01; default: 000)
COPIER>OPTION