COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
CHAPTER 5 SERVICE MODE
5-94 T
F-HUM-SW
Use it to turn on and off F-HUM-D if the environment senor has a fault (er-
ror).
•
Use it as an emergency remedy until the environment sensor is replaced.
Settings
0: OFF (default), 1: enables F-HUM-D
F-HUM-D
Use it to enter an approximate humidity level of the site of installation.
•
Uses the input humidity as the output of the humidity sensor.
•
Valid only if F-HUM-SW is set to '1'.
Settings
30% to 99% (default: 35%)
COPIER>OPTION