2B996-016JA
19
(1�3) Changing the setting in E�TRG mode
The E.TRG has three modes; 1P SR, PW SR, RR.
First move the “ ” to MODE and select E. TRG, then move the “ ” to E.TRG and select the desired E.TRG mode.
(1�3�1) Changing the setting in 1P SR mode
MODE
E.TRG
E.TRG
1P SR
TRG.P
EXP.
16ms
POSI
POSI
NEGA
PART
OFF
SHUTTER
0.03 ms 0.04 ms 0.4 ms 1 ms 16 ms
<MODE = E.TRG E.TRG = 1P SR>
• E.TRG mode
1P SR, PW SR, RR
• Input trigger pulse setting at 1P SR
• Exposure time setting at 1P SR
• Shutter mode MANU, SS, E.TRG, AUTO
Input trigger pulse : positive polarity
Input trigger pulse : negative polarity
Move up down
by pushing
MENU UP, DOWN
Select the desired
value by pushing
DATA UP, DOWN
0.01 ms
step
0.02 ms
step
0.1 ms
step
1 ms
step
• Turning partial scanning on/off
OFF : Partial scanning is off
ON : Partial scanning is on
You can set the area for partial scanning.
See "7.5 Partial Scanning".
EXT : You can switch between ON and OFF by using
external controls.
(a) Changing the polarity of the input trigger pulse setting
①
Move the “ ” to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
②
Select either POSI, NEGA, by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SR exposure time setting
①
Move the “ ” to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
②
Select the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
(c) To change the settings for partial scanning
①
Move the “ ” to PART by pushing the [MENU UP] and [MENU DOWN] buttons.
②
Select the mode you want by pushing the [DATA UP] and [DATA DOWN] buttons. (When ON or EXT is set)
③
Move the “ ” to the setting item you want by pushing the [MENU UP] and [MENU DOWN] buttons.
④
Select the setting values you want by pushing the [DATA UP] and [DATA DOWN] buttons.
* If PART is set to OFF, the setting values for partial scanning are not shown.