Chapter 2
2-34
T-2-6
4. Sheet-to-Sheet Temperature Control
The machine executes sheet-to-sheet temperature control to prevent overheating of the fixing pressure roller between sheets in continuous mode (low-speed
mode). The temperature of the fixing heater is lowered between sheets.
The sheet-to-sheet temperature, further, is varied depending on the distance between sheets and the type of paper used.
5. Throughput Reduction Control
The machine executes throughput reduction control to prevent overheating of the edges of the fixing heater during continuous printing on narrow paper.
If the reading of the sub thermistor exceeds a specific level in continuous printing, if the paper width sensor does not detect paper, or if the width of paper is less
than 195 mm, the machine will increase the distance between sheets to decrease throughput
T-2-7
2.6.3 Protective Functions
2.6.3.1 Outline
0010-6161
LBP5000 / LBP5100
The machine is equipped with the following 3 protective mechanisms to detect overheating of the fixing heater and cut power to the heater:
1. Protective Mechanism by the CPU
The CPU monitors the output voltage (MINTH, SUBTH) of the main/sub thermistor. If the voltage of MAINTH is about 0.84 V or less (equivalent of 225 deg
C or more), or if the voltage of SUBTH is about 2.12 V or more (equivalent of 245 deg C or more), the CPU will identify the condition as a fault in the fixing
assembly and execute the following:
1) The CPU stops the fixing heater drive signal (FSRD) to turn off the heater.
2) The CPU stops the relay drive signal (RLD).
3) The fixing heater safety circuit stops the main thermistor relay drive signal (RLD-).
4) The relay drive circuit opens the contact of the relay (RL901) to cut off power to the heater.
5) The machine stops printing operation, and indicates 'E001' in the status window.
2. Protective Mechanism by the Fixing Heater Safety Circuit
The fixing heater safety circuit monitors the output voltage (MAINTH, SUBTH) of the main/sub thermistor. If the voltage of MAINTH is about 0.6 V or less
(equivalent of 260 deg C or more), or if the voltage of SUBTH is about 2.8 V or more (equivalent of 270 deg C or more), the machine will identify the condition
as a fault in the fixing assembly and execute the following:
1) The fixing heater safety circuit stops the main thermistor relay drive signal (RLD-).
2) The fixing heater safety circuit stops the sub thermistor relay drive signal (RLD+).
3) The relay drive circuit turns off the relay (RL901) to cut off power to the heater.
3. Protective Mechanisms by the Thermal Fuse
The inside of the thermal fuse will melt at about 220 deg C, thereby cutting the power to the fixing heater.
2.6.3.2 Fault Detection
0010-6162
LBP5000 / LBP5100
The CPU will assume the presence of a fault in the fixing assembly in response to any of the forgoing conditions, and will stop the printer engine and indicate 'E001'
through 'E004' in the status window
1. Start-Up Fault (E002)
If the reading of the main thermistor is not 5 deg C or more (if at power-on, 0 deg C) 1 sec after the heater is turned on, the CPU will identify the condition as a
start-up fault.
2. Main Thermistor Error Temperature Low (E003-0000)
If the reading of the main thermistor is100 deg C (equivalent of about 2.60 V) or less continuously for 0.5 sec or more, the CPU will identify the condition as
an open circuit in the main thermistor.
3. Main Thermistor Error Temperature High (E001-000)
If the reading of the main thermistor is 225 deg C (equivalent of about 0.84 V) or more continuously for 0.5 sec or more, the CPU will identify the condition as
a main thermistor error temperature high.
4. Sub Thermistor Error Temperature Low (E001-0000)
If the reading of the sub thermistor is less than 100 deg C (equivalent of about 0.38) continuously for 0.5 sec or more, the CPU will identify the condition as a
sub thermistor error temperature low.
5. Sub Thermistor Error Temperature High (E001-0001)
If the reading of the sub thermistor is 245 deg C (equivalent of about 2.12 V) or more continuously for 0.5 sec or more, the CPU will identify the condition as a
sub thermistor error temperature high.
6. Drive Circuit Fault (E004)
If the zero-cross signal (ZEROX) is not detected for a specific period of time or more, the CPU will identify the condition as a drive circuit error.
2.7 EXTERNAL AND CONTROLS SYSTEM
2.7.1 Power Supply
2.7.1.1 Power Supply
2.7.1.1.1 Low-Voltage Power Supply PCB
0010-6165
LBP5000 / LBP5100
Paper type
Printer driver setting
No. 1 through No. 5 temperature
control
Plain paper
75 to 90g/m2
plain Paper
194 to 169
Plain paper
60 to 74g/m2
Plain Paper L
189 to 164
Heavy paper
91 to 120g/m2
Heavy Paper 1
165 to 150
Heavy paper
121 to 163g/m2
Heavy Paper 2
170 to 155
Envelope
Envelope
170 to 157
Transparency
Transparency
175 to 163
Print number of prints
1 to 4
5 to 11
The 12 sheet or later
Color
10
7
4
Black and white
12
8
4
Summary of Contents for LBP5000 Series
Page 1: ...Feb 26 2007 Service Manual LBP5000 5100 Series...
Page 2: ......
Page 6: ......
Page 14: ...Contents...
Page 15: ...Chapter 1 PRODUCT DESCRIPTION...
Page 16: ......
Page 18: ......
Page 28: ......
Page 29: ...Chapter 2 TECHNICAL REFERENCE...
Page 30: ......
Page 33: ...Contents 2 8 3 2 Overview of the Block 2 39...
Page 34: ......
Page 74: ...Chapter 2 2 40 IC12 Logic IC Converts voltage levels Notation Name Description...
Page 75: ...Chapter 3 DISASSEMBLY AND ASSEMBLY...
Page 76: ......
Page 80: ......
Page 122: ......
Page 123: ...Chapter 4 MAINTENANCE AND INSPECTION...
Page 124: ......
Page 126: ......
Page 132: ......
Page 133: ...Chapter 5 TROUBLESHOOTING...
Page 134: ......
Page 136: ......
Page 141: ...Chapter 5 5 5 F 5 9...
Page 142: ...Chapter 5 5 6 F 5 10...
Page 149: ...Chapter 6 APPENDIX...
Page 150: ......
Page 152: ......
Page 161: ...Feb 26 2007...
Page 162: ......