4
4
4-139
4-139
Disassembly/Assembly > Pickup And Feeding System > Removing the Pickup Unit Single-sided models (MF4450/MF4452/MF4453/MF4430/MF4420n/MF4410/MF4412)
Disassembly/Assembly > Pickup And Feeding System > Removing the Pickup Unit Single-sided models (MF4450/MF4452/MF4453/MF4430/MF4420n/MF4410/MF4412)
1-1-1) Remove the harness guide [1].
• 1 screw (black TP) [2]
• 1 wire saddle [3]
[1]
[2]
[3]
1-1-2) Remove the anti-noise plate [1].
• 1 screw (black TP) [2]
[2]
[1]
F-4-345
F-4-346
1-1-3) Remove the main controller mounting plate [1].
• 4 screws (with washer) [2]
• 2 screws (black TP) [3]
x6
[3]
[2]
[1]
1-2) Remove the main controller mounting plate [1].
• 3 screws (with washer) [2]
• 2 screws (black TP) [3]
x5
[1]
[2]
[3]
F-4-347
F-4-348