(2) Numeric value parameter
Parameter No.
Function
Setting range
01;
02;
T1 timer
0 to 9999 (x10ms)
03;
T2 timer
0 to 9999 (x10ms)
04;
T3 timer
0 to 9999 (x10ms)
05;
T4 timer
0 to 9999 (x10ms)
06;
Signal detection table
0 to 16
07;
Signal detection level
0 to 7
08;
Number of valid tone detection
0 to 9999 (times)
■
REORDER TONE
(1) Bit switch
Bit No.
Function
1
0
Bit 0
Bit 1
Signal detection method
FED
FR3
Bit 2
Signal frequency
Changed
Not changed
Bit 3
Bit 4
Judgment of intermittent signal
Start from valid ON
signal
Start from either valid
ON signal or OFF signal
Bit 5
Bit 6
Signal form
Continuous
Intermittent
Bit 7
Signal detection
Detected
Not detected
(2) Numeric value parameter
Parameter No.
Function
Setting range
01;
02;
T1 timer
0 to 9999 (x10ms)
03;
T2 timer
0 to 9999 (x10ms)
04;
T3 timer
0 to 9999 (x10ms)
05;
T4 timer
0 to 9999 (x10ms)
06;
Signal detection table
0 to 16
07;
Signal detection level
0 to 7
08;
Number of valid tone detection
0 to 9999 (times)
T-8-31
T-8-32
T-8-33
■
AUTO RX
(1) Numeric value parameter
Parameter No.
Function
Setting range
01;
CI ON time
0 to 9999 (x10ms)
02;
Cl long off time
0 to 9999 (x10ms)
03;
Cl off time
0 to 9999 (x10ms)
04;
CL long off time
0 to 9999 (x10ms)
05;
Cl MAX off time
0 to 9999 (x10ms)
06;
Cl wait time
0 to 9999 (x10ms)
07;
CI frequency
0 to 9999 (cycle)
08;
CI frequency lower limit
0 to 9999 (Hz)
09;
CI frequency upper limit
0 to 9999 (Hz)
■
CNG DETECT
(1) Numeric value parameter
Parameter No.
Function
Setting range
01;
At F/T switching CNG MIN ON time
0 to 9999 (x10ms)
02;
CNG MAX ON time
0 to 9999 (x10ms)
03;
04;
05;
06;
Hit ratio
0 to 9999 (%)
07;
At direct
connecting to
answering phone
CNG MIN ON time
0 to 9999 (x10ms)
08;
CNG MAX ON time
0 to 9999 (x10ms)
09;
Tolerable time of
instantaneous
interruption
0 to 9999 (x10ms)
10;
11;
Number of detection
0 to 9999 (Times)
12;
Hit ratio
0 to 9999 (%)
■
RKEY
(1) Numeric value parameter
Parameter No.
Function
Setting range
01;
Connection time of flash
0 to 9999 (x10ms)
02;
Connection time of grounding wire 0 to 9999 (x10ms)
03;
T-8-34
T-8-35
T-8-36
Summary of Contents for MF4500 Series
Page 222: ...5 5 Adjustment Adjustment Mechanical Adjustment ...
Page 224: ...6 6 Trouble Shooting Trouble Shooting Test Print Trouble Shooting Items Version Upgrade ...
Page 230: ...7 7 Error Codes Error Codes Overview Error Codes ...
Page 234: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 251: ... Service Tools Solvent Oil List General Circuit Diagram General Timing Chart Appendix ...