37
MAINTENANCE AND TROUBLESHOOTING
Troubleshooting
If you are having a problem with the MS500, refer to this table to
see if you can identify the cause and find the solution.
Problem
Solution
Screen does not come on, even after turning
• Check the lamp unit and make sure it is set securely.
on the power switch.
• Check the lamp to see if the lamp is burnt out. After the lamp
burns out, L5 is displayed. If the lamp is burned out, change the
halogen lamp. (
➞
34)
Screen brightness is uneven or too dark.
• Check the lens and make sure it is clean. (
➞
34)
• Check the lens and make sure it is correctly installed.
• Check the lamp and lamp unit and make sure both are installed
securely. (
➞
34)
Image is out of focus.
• Adjust the focus with the Image Adjust Control dial. (
➞
17)
• Check and make sure the lens and lens holder are correctly
installed. (
➞
10)
• Check the carrier and make sure that it is installed correctly. For
details, read the instructions you received with the carrier.
• Check the lens and lamp and make sure they are clean. If re-
quired, clean the lens and/or lamp. (
➞
36)
Image is skewed.
• Adjust the rotation using the Image Adjust Control dial. (
➞
18)
• Check the carrier and make sure that it is installed correctly.
For details, read the instructions you received with the carrier.
After pressing the Print key, print will not start.
• If the lamp next to the Print Start key on the keyboard is red,
the unit is still warming up. Wait for the lamp to turn green before
trying to print. (
➞
16)
• If the Print display shows a User Call Error, look it up in the
table. (
➞
38)
Summary of Contents for Microfilm Scanner 500
Page 47: ......