CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-47
10. Checking the Photointerrupters
1) Set the meter range to 12 VDC.
2) Connect the - probe [1] of the meter to the grounding terminal [2].
Sensor
PS1
Scanner home position
sensor (SCHP)
PS2
Lens home position sen-
sor (LHP)
PS4
Vertical path roller pa-
per sensor (PDP)
Q751
Pre-registration roller
paper sensor (RPD)
Checks
During standby, move
the scanner by hand.
During standby, move
the lens mount by
hand.
During standby, move
the detecting lever by
hand.
During standby, move
the detecting lever by
hand.
When the light-block-
ing plate is at PS1,
When the light-block-
ing plate is not at PS1,
When the light-block-
ing plate is at PS2,
When the light-block-
ing plate is not at PS2,
When the light-block-
ing plate is at PS4,
When the light-block-
ing plate is not at PS4,
When the light-block-
ing plate is at Q751,
When the light-
blocking plate is not at
Q751,
Connector
J101-3
J109-10
J132-5
J108-1
Voltage
(approx.)
5V
0V
5V
0V
5V
0V
0V
5V
[1]
[2]
Table 2-9
Figure 2-68
3) Make checks as instructed.
Reference:
The photointerrupers other than those shown in Table 2-9 are connected in a matrix, hence the
omission from the table.
Summary of Contents for NP6412
Page 6: ......
Page 12: ......
Page 34: ......
Page 46: ......
Page 48: ......
Page 92: ......
Page 144: ......
Page 176: ......
Page 178: ......
Page 192: ......
Page 194: ......
Page 220: ......
Page 222: ......
Page 256: ......
Page 258: ......
Page 282: ......
Page 284: ......
Page 286: ......
Page 384: ......
Page 388: ......
Page 414: ......
Page 424: ......
Page 430: ......
Page 432: ......
Page 434: ......
Page 484: ......
Page 492: ......
Page 502: ......
Page 506: ......
Page 516: ......
Page 599: ...PRINTED IN JAPAN IMPRIME AU JAPON ...